Article successfully added.

CyFlow™ CD62P FITC

CyFlow™ CD62P FITC
Alternative Name: P-selectin
Antibody: Yes
Antigen: CD62P
Application: Flow cytometry
Clonality: monoclonal
Clone: AK4
Emission Maximum: 518 nm
Excitation Maximum: 490 to 495 nm
Field of Interest: Immunophenotyping
Format/Fluorochrome: FITC
Isotype: IgG1
Laser: Blue
Regulatory Status: RUO
Source Species: Mouse
Target Species: Human, Non-Human Primates
Product number: CB156548

For Research Use Only

$235.00 USD*

Price excludes any applicable taxes plus shipping costs

HLDA Workshop HLDA VI—WS Code P-44 Quantity 100 tests Volume 0.4 mL Immunogen... more
CyFlow™ CD62P FITC

HLDA WorkshopHLDA VI—WS Code P-44
Quantity100 tests
Volume0.4 mL
ImmunogenHuman platelets
Background InformationCD62P (P-selectin) is an adhesion glycoprotein that is expressed on platelets and endothelial cells upon their activation. Interaction between CD62P and its mucin-like ligand PSGL-1 (P-selectin glycoprotein ligand-1) expressed on the microvilli of most leukocytes supports leukocyte rolling along postkapillary venules at the earliest time of inflammation. Both CD62P and PSGL-1 are extended glycoproteins that form homodimers. CD62P dimerization is probably mediated through interactions of the transmembrane domains and stabilizes leukocyte tethering and rolling, probably by increasing rebinding within a bond cluster.
UsageThe reagent is designed for Flow Cytometry analysis of human blood cells. Recommended usage is 4·µl reagent·/ 100·µl of whole blood or 10^6 cells in a suspension. The content of a vial (0.4 ml) is sufficient for 100 tests.
Storage BufferThe reagent is provided in stabilizing phosphate buffered saline (PBS) solution, pH ≈7.4, containing 0.09% (w/v) sodium azide.
StorageAvoid prolonged exposure to light. Store in the dark at 2-8°C. Do not freeze.
StabilityDo not use after expiration date stamped on vial label.

Specific References

| Dunlop LC, Skinner MP, Bendall LJ, Favaloro EJ, Castaldi PA, Gorman JJ, Gamble JR, Vadas MA, Berndt MC: Characterization of GMP‑140 (P‑selectin) as a circulating plasma protein. J Exp Med. 1992 Apr 1; 175(4):1147‑50. < PMID: 1372646 > | Holme PA, Müller F, Solum NO, Brosstad F, Frøland SS, Aukrust P: Enhanced activation of platelets with abnormal release of RANTES in human immunodeficiency virus type 1 infection. FASEB J. 1998 Jan; 12(1):79‑89. < PMID: 9438413 > | Kowalska MA, Ratajczak J, Hoxie J, Brass LF, Gewirtz A, Poncz M, Ratajczak MZ: Megakaryocyte precursors, megakaryocytes and platelets express the HIV co‑receptor CXCR4 on their surface: determination of response to stromal‑derived factor‑1 by megakaryocytes and platelets. Br J Haematol. 1999 Feb; 104(2):220‑9. < PMID: 10050701 > | Ludwig RJ, Schultz JE, Boehncke WH, Podda M, Tandi C, Krombach F, Baatz H, Kaufmann R, von Andrian UH, Zollner TM: Activated, not resting, platelets increase leukocyte rolling in murine skin utilizing a distinct set of adhesion molecules. J Invest Dermatol. 2004 Mar; 122(3):830‑6. < PMID: 15086572 >